Commands Listed in Alphabetical Order
BUS:B<x>:RS2
32C:DATABits
Sets or returns the number of RS232 data bits for bus <x>, where x is the bus
number.
Conditions
This command requires a DPO2COMP application module.
Group
Bus
Syntax
BUS:B<x>:RS232C:DATABits {7|8|9}
BUS:B<x>:RS232C:DATABits?
Arguments
7 species seven bits in the RS232 data frame.
8 species eight bits in the RS232 data frame.
9 species nine bits in the RS232 data frame.
BUS:B<x>:RS232C:DELIMiter
Sets or returns the RS232 delimiting value for a packet on bus <x>, where x
is the bus number.
Conditions
This command requires a DPO2COMP application module.
Group
Bus
Syntax
BUS:B<x>:RS232C:DELIMiter {NULl|LF|CR| SPace|XFF}
BUS:B<x>:RS232C:DELIMiter?
Arguments
NULl species 0x00.
LF species 0x0A.
CR species 0x0D.
XFF species 0xFF.
BUS:B<x>:RS232C:DISplaymode
Sets or returns the display mode for the bus <x> display and event table, where x
is the bus number.
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-83
Vue de la page 98