Connect-Tek USB-2 Spécifications Page 333

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 441
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 332
Commands Listed in Alphabetical Order
Examples
TRIGGER:A:LEV
EL:AUXIN E CL
sets the auxiliary input trigger level to -1.3
volts.
TRIGGER:A:LE
VEL:AUXIN?
might return TRIGGER:A:LEVEL:AUXIN 0.0E+0
indicating that the auxiliary input trigger level is 0.0 volts.
TRIGger:A:LEVel:CH<x>
Sets or returns the trigger level for the specied channel. Each channel can have
an independent level.
Group
Trigger
Syntax
TRIGger:A:LEVel:CH<x> {<NR3>|TTL|EC L}
TRIGger:A:LEVel:CH<x>?
Arguments
<NR3> species the trigger level in user units (usually volts).
TTL species a preset TTL high level of 1.4 V.
ECL species a preset ECL high level of –1.3 V.
Examples
TRIGGER:A:LEVEL:CH2? might return :TRIGGER:A:LEVEL:CH2
1.3000E+00
indicating that the A edge trigger is set to 1.3 V for channel 2.
TRIGGER:A:LEVEL:CH3 TTL sets the A edge trigger to TTL high level for
channel 3.
TRIGger:A:LEVel:D<x>
Sets or returns the trigger level for the specied digital channel <x>, where x is
the channel number. The digital channels do not have independent trigger levels.
Channels D0–D7 share one common trigger level and D8–D15 share another
common trigger level. For example: Changing the trigger level for D3 changes
the levels for D0–D7.
Group
Trigger
Syntax
TRIGger:A:LEVel:D<x> {<NR3>|ECL|TTL }
TRIGger:A:LEVel:D<x>?
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-317
Vue de la page 332
1 2 ... 328 329 330 331 332 333 334 335 336 337 338 ... 440 441

Commentaires sur ces manuels