Commands Listed in Alphabetical Order
AUTOSet:ENAb
le
Enables or disables the autoset.
Group
M
iscellaneous
Syntax
AUTOSet:ENAble {OFF|ON}
AUTOSet:ENAble?
Related Commands
AUTOSet
Arguments
ON enables the autoset feature.
OFF disables the autoset feature.
Examples
AUTOSET:ENABLE ? might return AUTOSET:ENABLE 1 indicating that autoset is
enabled.
AUTOSET:ENABLE OFF disables autoset.
AUXin? (Query Only)
Returns all auxiliary input parameters.
Group
Vertical
Syntax
AUXin?
AUXin:PRObe
Returns all information concerning the probe attached to auxiliary input.
Group
Vertical
Syntax
AUXin:PRObe
AUXin:PRObe?