Command Groups
Horizontal Co
mmand Group
Use the commands in the Horizontal Command Group to control the oscilloscope
time bases. You can set the time-per-division of the main time base. You can also
use the Horiz
ontal commands to set the scale, horizontal position, and reference
of the time base.
Table 2-23: Horizontal Commands
Command
Description
HORizontal? Returns settings for the horizontal commands
HORizontal:ACQLENGTH?
Returns the record length
HORizontal:DELay:MODe Sets or returns the horizontal delay mode
HORizontal:DELay:TIMe Sets or returns the horizontal delay time
HORizontal:DIGital:RECOrdlength:MAIN? Returns the record length of the main digital
acquis
ition
HORizo
ntal:DIGital:SAMPLERate:MAIN?
Return
s the sample rate of the main digital
acquisition
HORizontal:POSition Sets or returns the horizontal position
HORizontal:PREViewstate?
Retu
rns whether or not the acquisition
system is in the preview state
HORizontal:RECOrdlength Sets the horizontal record length to the
number of data points in each frame
Or r
eturns the c urrent horizontal record
length
HORizontal:RESOlution Sets or returns the horizontal record length
to the number of data points in each frame
HORizontal:SAMPLERate Sets or returns the c urrent horizontal sample
ra
te
H
ORizontal:SCAle
S
ets or returns the time base horizontal scale
HORizontal:TRIGger:POSition Sets the horizontal position when delay
mode is OFF
Mark Command Group
Use the commands in the Mark Command Group to identify areas of the acquired
waveform that warrant further investigation.