Connect-Tek USB-2 Spécifications Page 90

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 441
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 89
Commands Listed in Alphabetical Order
Syntax
BUS:B<x>:CAN:
PRObe {CA NH|CANL|RX|TX|DI FFerential}
BUS:B<x>:CAN:PRObe?
Arguments
CANH species the single-ended CANH signal, as specied by the CAN standard.
CANL species the single-ended CANL signal, as specied by the CAN standard.
RX species the receive signal on the bus side of the CAN transceiver.
TX species the transmit signal.
DIFFerential species the differential CAN signal.
BUS:B<x>:CAN:SAMPLEpoint
Sets or returns the sampling point during each bit period for bus <x>, where x
is the bus number
Conditions
This command requires a DPO2AUTO application m odule.
Group
Bus
Syntax
BUS:B<x>:CAN:SAMPLEpoint <NR1>
BUS:B<x>:CAN:SAMPLEpoint?
Arguments
<NR1> is the sample point in percent. Values are limited to 25, 30, ... 70, 75.
BUS:B<x>:CAN:SOUrce
Sets or returns the CAN bus data source for bus <x>, where x is the bus number.
Conditions
This command requires a DPO2AUTO application m odule.
Group
Bus
Syntax
BUS:B<x>:CAN:SOUrce {CH1|CH2|CH3|CH 4|
D0|D1|D2|D3|D4|D5|D6|D7|D 8|D9|D10|D11|D12|D13|D14|D15}
BUS:B<x>:CAN:SOUrce?
2-74 MSO2000B, DPO2000B, MSO2000 and DPO2000 Series O scilloscopes Programmer Manual