Commands Listed in Alphabetical Order
TRIGger (No Qu
ery Form)
Forces a trigger event to occur.
Group
Trigger
Syntax
TRIGger FORCe
TRIGger?
Arguments
FORCe creates a trigger event. If TRIGger:STATE is set to READy, the acquisition
will complete. Otherwise, this command will be ignored.
Examples
TRIGGER FORCE forces a trigger event to occur.
TRIGger:A
Sets the A trigge
r level automatically to 50% of the range of the minimum and
maximum values of the trigger input signal. The query returns current A trigger
parameters. The trigger level is the voltage threshold through which the trigger
source signal must pass to generate a trigger event. This command works for the
following cases: Edge Trigger (when source is Not Line), Logic Trigger (when
Clock Source is not Off or Logic Pattern is Don't Care), and Pulse Width Trigger.
Group
Trigger
Syntax
TRIGger:A SETLevel
TRIGger:A?
Related Commands
TRIGger:A:EDGE?, TRIGger:A:LOGIc?, TRIGger:A:PULse?
Arguments
SETLevel sets the A trigger
level to 50% of the range of the minimum and
maximum values of the trigger input signal.
Examples
TRIGGER:A SETLEVEL sets
the A trigger level to 50% of the range of the
minimum a nd maximum values of the trigger input signal.
TRIGGER:A? might return a long response with A trigger parameters,
some of which could be as follows:
:TRIGGER:A:MODE AUTO;TYPE
EDGE;LEVEL 20.0000E-3;LEVEL:CH1 20.0000E-3;CH2 0.0000;
CH3 0.0 000;CH4 0.0000;:TRIGGER: A:UPPERTHRESHOLD :CH1
1.4000;CH2 800.0000E-3;CH3 8 00.0000E-3;CH4
2-294 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual