Commands Listed in Alphabetical Order
<NR1> = 0 sets th
e Horizontal Delay Mode to off; any other value sets this mode
to on.
Examples
HORIZONTAL:DELAY:MODE OFF sets the Horizontal Delay Mode to off, allowing
the HORizontal:POSition command to horizontally position the waveform.
HORIZONTAL:DELAY:MODE? might return HORIZONTAL:DELAY:M ODE OFF
indicating that the HORizontal:POSition command horizontally positions the
waveform.
HORizontal:DELay:TIMe
Sets or returns the horizontal delay time. The amount of time the acquisition is
delayed depends on sample rate and record length.
Group
Horizontal
Syntax
HORizontal:DELay:TIMe <NR3>
HORizontal:DELay:TIMe?
Arguments
NR3 is the delay in seconds.
Examples
HORizontal:DELay:TIME 0.3 sets the delay of acquisition data so that the
resulting waveform is centered 300 ms after the trigger o ccurs.
HORizontal:DIGital:RECOrdlength:MAIN? (Query Only)
Returns the record length of the main digital acquisition.
Group
Horizontal
Syntax
HORizontal:DIGital:RECOrd length:MAIN?
HORizontal:DIGital:SAMP
LERate:MAIN? (Query Only)
Returns the sample rate of the main digital acquisition.
Group
Horizontal
2-168 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual