Connect-Tek USB-2 Spécifications Page 375

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 441
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 374
Commands Listed in Alphabetical Order
Syntax
WFMInpre:XINc
r <NR3>
WFMInpre:XINcr?
Related Commands
WFMInpre:XUNit, WFMOutpre:XINcr?
Arguments
<NR3> is the horizontal interval representation.
Examples
WFMINPRE:XINCR 3E-3 sets the interval between incoming waveform points
to3ms.
WFMINPRE:XINCR ? might return :WFMINPRE:XINCR 1.0000E-3 indicating
that if WFMInpre:XUNit is set to "s", there is a 1 ms interval between incoming
waveform points.
WFMInpre:XUNit
Sets or returns the horizontal units of the incoming waveform.
Supported units are:
%, /Hz, A, A/A, A/V, A/W, A/dB, A/s, AA, AW, AdB, As, B, Hz, IRE, S/s, V,
V/A, V/V, V/W, V/dB, V/s, VV, VW, VdB, Volts, Vs, W, W/A, W/V, W/W, W/dB,
W/s,WA,WV,WW,WdB,Ws,dB,dB/A,dB/V,dB/W,dB/dB,dBA,dBV,dBW,
dBdB, day, degrees, div, hr, min, ohms, percent, s
Group
Waveform Transfer
Syntax
WFMInpre:XUNit <QString>
WFMInpre:XUNit?
Related Commands
WFMOutpre:XUNit?
Arguments
<QString> contains a maximum of three alpha characters that represent the
horizontal unit of measure for the incoming waveform.
Examples
WFMINPRE:XUNIT "HZ" species that the horizontal units for the incoming
waveform are hertz.
WFMINPRE:XUNIT? might return :WFMINPRE:XUNIT "s" indicating that the
horizontal units for the incoming waveform are seconds.
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-359