Application Note
www.tektronix.com/usb8
Impedance Measurement Test
Due to the high signal rates of USB 2.0 High-Speed mode,
trace and packaging impedance have become critical
parameters. The USB 2.0 High-Speed specification now
requires differential impedance measurements of cables,
silicon and devices.
The USB 2.0 specification requires that the differential
TDR impedance step response be set to 400 ps. The USB
specification defines the impedance limits referenced from the
DUT connector. In general, the impedance should be between
70 Ohm and 110 Ohm at a given distance from the connector.
Cables are also required to meet specific impedance limits.
These limits are 90 Ohm +/- 15%.
Test Equipment
The impedance measurement test requires a time domain
reflecto-meter, such as the DSA8200 digital serial analyzer
sampling oscilloscope with 80E04 TDR sampling module,
which offers unmatched TDR performance on up to eight
channels simultaneously. Add the IConnect product to convert
from TDR measurements to S-parameters.
Figure 10 shows a TDR measurement made with the
DSA8200 sampling oscilloscope. The Min and Max measure
within the tolerance specified by the USB differential
specification of 90 Ohm +/- 15%.
Instrumentation Requirements for USB
2.0 Physical Layer Testing
USB 2.0 opens up a whole range of USB consumer
applications to make the PC a more user friendly and valuable
tool in the workplace and home. With any consumer product
opportunity, time to market is crucial. USB designers are
keenly aware that the correct tool aids in meeting schedule
objectives. Especially critical are the bandwidth, rise time and
sample rate of the oscilloscope, along with the test fixture and
fully automatic test software.
USB 2.0 physical layer validation and electrical compliance
testing require a host of test equipment, as the chart above
illustrates.
Figure 10. TDR measurement made with a DSA8200 sampling oscilloscope coupled
with an 80E04 TDR sampling module.
Test
Equipment
Signal
Quality
Test
Inrush
Current
Check
Droop
Test
Receiver
Sensitivity
Test
CHIRP
Test
Impedance
Measurement
Test
Real-time
Oscilloscope
Y Y Y Y Y
Time Domain
Reflectometer
Y
Data Generator Y
Test Fixture Y Y Y Y Y Y
Test Software Y Y Y Y Y
Differential
Probes
Y Y
Single-ended
Probes
Y Y Y
Current Probes Y