Application Note
www.tektronix.com/usb6
Test Equipment
The receiver sensitivity test requires a real-time oscilloscope,
such as a MSO/DPO5204 or DPO7254 or higher bandwidth
model, and a highspeed data source that can transmit IN
tokens of varying amplitude, such as a Tektronix AWG5000
or AWG7000C Series Arbitrary Waveform Generator. This test
also requires differential probes, like a TDP1500, TDP3500, or
P6248
*3
, and test software and a test fixture.
Figure 5 shows the set-up to perform this test using an
oscilloscope and data generator. The option USB test
package provides various test set-ups and the test patterns
for the signal source, needed for receiver sensitivity testing.
CHIRP Test
The CHIRP test examines the basic timing and voltages of
both upstream and downstream ports during the speed
detection protocol. For a hub, the CHIRP test must be
performed on both upstream and downstream ports.
To perform CHIRP testing, the DUT is hot-plugged and
signaling is measured with single-ended probes on both
data lines. Data is analyzed for CHIRP K amplitude, CHIRP
K duration, Reset duration, Number of KJ pairs before High
Speed termination and delay after KJKJKJ before device-
applied termination.
Figure 6 illustrates the CHIRP test using a DPO7254.
Test Equipment
The CHIRP test requires a 2 GHz or higher bandwidth realtime
oscilloscope, such as a MSO/DPO5204 or DPO7254, with
single-ended probes, like a TAP1500, TAP2500, TAP3500,
P6243
*3
or P6245
*3
. In addition, this test requires test software
and a test fixture, such as the option USB compliance test
package.
Manual analysis of the various CHIRP types and conditions is
a time-consuming process. The test package automates this
process and automatically documents the results.
Test Mode
SW
SMA
Oscilloscope
Data Generator
USB 2.0 Test Fixture
HS Device
Figure 5. Set-up for a receiver sensitivity test using a DPO7254 and a
Tektronix signal source.
Figure 6. Test parameters for a CHIRP test.
*3
Requires a TPA-BNC adapter when used on an MSO/DPO5000 or DPO7000 Series model.